Sub btnApply_EventClick()
Dim This : Set This = btnApply
FmsHistoryGraph.SessionNodeTag = editSessionNode.Text
FmsHistoryGraph.SessionBeginDate = editStartDate.Text
FmsHistoryGraph.SessionEndDate = editEndDate.Text
FmsHistoryGraph.PITDateTime = editPIT.Text
FmsHistoryGraph.UsePIT = checkUsePIT.Check
FmsHistoryGraph.Apply True
End Sub
Sub btnCancel_EventClick()
Dim This : Set This = btnCancel
FmsHistoryGraph.Cancel
End Sub
Sub checkUsePIT_EventChange()
Dim This : Set This = checkUsePIT
FmsHistoryGraph.UsePIT = this.Check
editPIT.Enable this.Check
End Sub
Sub TheView_EventInitialize()
Dim This : Set This = TheView
editSessionNode.Text = FmsHistoryGraph.SessionNodeTag
editStartDate.Text = FmsHistoryGraph.SessionBeginDate
editEndDate.Text = FmsHistoryGraph.SessionEndDate
checkUsePIT.Check = FmsHistoryGraph.UsePIT
editPIT.Text = FmsHistoryGraph.PITDateTime
editPIT.Enable = FmsHistoryGraph.UsePIT